1.
Chinese Journal of Infectious Diseases ; (12): 264-269, 2022.
Article in Chinese | WPRIM | ID: wpr-956428

ABSTRACT

Objective:To explore the clinical characteristics of patients infected with 2019 novel coronavirus (2019-nCoV) Omicron variant in Zhuhai City.Methods:A retrospective study was conducted to compare the clinical characteristics of patients infected with 2019-nCoV Omicron variant (Omicron variant group, 39 cases) from January 13 to January 25, 2022, and those infected with 2019-nCoV non-Omicron variant (non-Omicron variant group, 98 cases) from January 17 to February 17, 2020, in the Fifth Affiliated Hospital of Sun Yat-sen University. Statistic methods were used by Mann-Whitney U test, chi-square test and Fisher exact probability test. Results:Among adults, the age of 21 patients in Omicron variant group was younger than that of 93 patients in non-Omicron variant group (34.0(26.0, 40.5) years vs 50.0(36.0, 62.0) years, Z=-3.81, P<0.001). Patients with underlying diseases in Omicron variant group were fewer than those in non-Omicron variant group (4.8%(1/21) vs 31.2%(29/93), χ2=6.17, P=0.013). The clinical classification of the Omicron variant group was mainly mild (71.4%(15/21)) or common type (28.6%(6/21)), while the non-Omicron variant group was dominated with common type (57.0%(53/93)) and severe type (23.7%(22/93)), and the clinical classification of the two groups had statistically difference ( χ2=31.79, P<0.001). The time of positive nucleic acid in Omicron variant group was longer than that in non-Omicron variant group (14.0(10.5, 16.5) d vs 8.5(4.0, 12.0) d, Z=-3.56, P<0.001). The proportion of pneumonia in Omicron variant group was less than that in non-Omicron variant group (28.6%(6/21) vs 86.0%(80/93), χ2=30.52, P<0.001). Differences were all statistically significant. There was no significant difference of the clinical characteristics in pediatric patients, but the proportion of children infected with 2019-nCoV Omicron variant was significantly higher than that infected with 2019-nCoV non-Omicron variant (46.2%(18/39) vs 5.1%(5/98), χ2=33.65, P<0.001). Conclusions:Adults infected with 2019-nCoV Omicron variant in Zhuhai City present with milder clinical symptoms, less proportion of pneumonia, but the time of positive nucleic acid is longer. The clinical characteristics of children infected with 2019-nCoV Omicron variant are not specific, while the proportion of children infected with 2019-nCoV Omicron variant is significantly higher.

2.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 537-543, 2018.
Article in Chinese | WPRIM | ID: wpr-810050

ABSTRACT

Implantable bone-conduction devices are characterized by the fact that the vibration is transmitted through bone conduction. The technology and surgical techniques in the application of implantable bone-conduction devices have developed considerably in recent years, experiencing a transformation from percutaneous to transcutaneous implantation. This article reviewed current developments in the types, surgical indications, and complications, as well as compared between the various bone-conduction devices to provid references for clinical application.

3.
Journal of Audiology and Speech Pathology ; (6): 181-185, 2018.
Article in Chinese | WPRIM | ID: wpr-698127

ABSTRACT

Objective To investigate the speech recognition in noise in patients with unilateral conductive or mixed hearing impaired using Sophonotron Alpha 2 softband.Methods A total of 12 patients (12 ears) with unilateral conductive or mixed hearing loss participated in the survey and fitted with Sophonotron Alpha 2.The aided hearing threshold test and speech recognition test in noise were evaluated in both unaided and aided conditions.Results The average aided hearing threshold using Sophonotron Alpha 2 softband was 35.0±10.8 dB HL,showing significant improvement compared to that of unaided(P<0.05).The average signal-to noise ratio loss was 5.9± 6.1 dB using Sophonotron Alpha 2 softband in noise,showing a more significant benefit than that of the unaided (13.6±10.9 dB).Conclusion The Sophonotron Alpha 2 softband can significantly improve speech recognition in noise for the patients with unilateral conductive or mixed hearing loss.

4.
Journal of Audiology and Speech Pathology ; (6): 506-510, 2017.
Article in Chinese | WPRIM | ID: wpr-607339

ABSTRACT

Objective The aim of the study was to evaluate the hearing performance of a new transcutaneous bone conduction hearing aid.Methods One hundred and nine patients with conductive or mix hearing loss and eleven patients with single sided sensorineural hearing loss from four tertiary referral centers were tested under unaided and aided conditions with the sound processors on testbands.Free field test was performed to obtain the hearing thresholds and speech recognition thresholds in quiet.Adverse events were also documented by a self-reported questionnaire.Results ①Conductive or mixed hearing loss patients:for aged≥6 yrs subgroup,the bone conduction PTA average of aided sides was 18.55±8.99 dB HL.For aged<6 yrs subgroup, the bone conduction ABR hearing threshold average was 18.33±8.36 dB HL.②Statistically significant improvements in free field hearing thresholds were seen when compared aided hearing with unaided outcomes.The average PTA (pure tone average in free field) was measured at 32.21±10.00, 37.33±14.15, and 34.38±10.76 dB HL respectively in conductive or mixed hearing loss aged≥6 yrs subgroup;aged<6 yrs subgroup and SSD subgroup.③In aided situations;speech recognition thresholds in quiet were significantly better compared to unaided situation in patients aged≥6yrs.④None of patients presented adverse events related to the devices.Conclusion The Sophono bone conduction hearing aid has satisfactory hearing performance and can be considered an alternative device for patients with conductive or mix hearing loss or with SSD.